MR Pediatric Neck/Chest W Protocol

Scan Notes:   Images must be checked by radiologist or radiology resident before giving contrast and before the patient gets off the table. 

Last updated:3/28/19
Charge as:  Chest W
Scanner preference: 1.5T or 3T
Coil: Torso or Cardiac

Plane Weighting Mode Slice Gap FAT SAT FOV Notes
AXIAL 2D TOF FFE 4mm -2mm* None Fit to Patient Carina to basilar artery. Include aortic arch, carotids, vertebral arteries in slice FOV. *Over-contiguous images

Contrast injection

Plane Weighting Mode Slice Gap FAT SAT FOV Notes
COR CE 3D TOF FFE 1.2mm 0mm None Fit to Patient Carina to basilar artery. Include aortic arch, carotids, vertebral arteries in slice FOV