MR Novartis CLCI699 Research Protocol

Scan notes:

  • This is a pituitary research study.
  • Patient will need a 22g IV
  • Injection is the same as for our routine dynamic pituitary

Last updated: 4/12/19
Charge as: Brain W/WO
Scanner preference: MR1 only
Coil: Head coil 

Sequence Weighting Change Parameters? Change # slices? Coverage/ Angulation Notes
SAG T1 NO NO Angle to Midline Whole Brain Coverage
SAG T1 (Thin) NO NO Angle to Midline Only cover the Pituitary
COR T1 (Thin) NO NO Angle to Pituitary Only cover the Pituitary

Dynamic contrast Injection

Sequence Weighting Change Parameters? Change # slices? Coverage/ Angulation Notes
COR DYNAMIC DYNAMIC NO NO Angle to Pituitary Only cover the Pituitary
SAG T1 (Thin) NO NO Angle to Midline Only cover the Pituitary
COR T1 (Thin) NO NO Angle to Pituitary Only cover the Pituitary
AX T1 NO NO Angle to AC-PC Line Whole Brain Coverage