MR ED Infection Screening Total Spine W

Indication:

This abbreviated total spine MRI is to be used for the purpose of ruling-out infection in the spine. 

Optional Axial T2 and Optional Axial +T1 coverage:

These axial sequences should only be performed through the level(s) of potential infection as seen on sagittal images, at the technologist’s discretion. If unsure, call radiologist for guidance.

Other notes:

Last updated: 5/17/22

Charge as: Total Spine W

Scanner preference: None 

Coil: On all of our systems except MR1, add the torso coil anteriorly in combination with the table top and/or NV array coils.

Plane Weighting Mode Slice (mm) Gap (mm) FAT SAT FOV (cm) MPR Notes
HAND INJECT CONTRAST.
Upper Station - Pre-contrast
SAG T2 2D TSE 3 0.3 Dixon: InPhase & Water only no
SAG T1 2D TSE 3 0.3 Dixon: InPhase & Water only no
Lower Station - Pre-contrast
SAG T1 2D TSE 3 0.3 Dixon: InPhase & Water only no
SAG T2 2D TSE 3 0.3 Dixon: InPhase & Water only no
Optional (see note)
AXIAL T1 VIBE/THRIVE 3 0 YES 15 no Optional. See note above.
AXIAL T2 2D TSE 3 0.3 no 15 no Optional. See note above.