Scan Notes: 
Earplugs only. 
No headphones. 
Use positioning sponges carefully at the level of the patient’s chin if needed. 
No angles. 
Cover the entire nose. 
Cover below skull base to at least 1 cm above Vertex. 
Include additional air on top of scan for slice wrap.

Last updated:3/21/2019
Charge as: Brain WO, Brain W or Brain WWO
Scanner preference: 1.5T or 3T
Coil: Head

Plane Weighting Mode Slice Gap FAT SAT FOV Notes
AXIAL 3D T1 FFE 3D GRE 1.3 mm 0mm None 25cm No angles. INCLUDE ADDITIONAL AIR ON TOP OF SCAN FOR SLICE WRAP
AXIAL T2 VISTA TSE 1.3mm 0mm None 25cm No angles. INCLUDE ADDITIONAL AIR ON TOP OF SCAN FOR SLICE WRAP
AXIAL (run only if requested) FLAIR TSE 1.3mm 0mm None 25cm No angles. INCLUDE ADDITIONAL AIR ON TOP OF SCAN FOR SLICE WRAP