MR Novartis CCNP520A2202J (5175) (Subject) Research Protocol

Revised - 12/18/2018
Charge as Brain WO
No Read

Novartis CCNP520A2202J / Generation Study 2
Link to PDF info sheet


What would Joe do? (WWJD)
No read
MR4 - Head Coil
Sequence   Change Parameters? Change # slices? Coverage/ Angulation Notes
SAG 3D T1 TFE NO NO Be sure to cover the brain both LR and AP. Be sure to cover the brain both LR and AP. Leave about 15 mm from top of the head to the top of the FOV.
image
Axial FLAIR NO NO Angle parallel to AC-PC line Acquisition stack must fully cover subject's brain, starting at the vertex down to the cerebellum
image
Axial T2* GRE NO NO Same as Axial Flair Same as Axial Flair
Dual Echo PD/T2 NO NO Same as Axial Flair Same as Axial Flair
AX DWI NO NO No angleNo angle. Send source images to PACS
AX DTI NO NO No angle No angle. Send source images to PACS
AXIAL FIELD MAP NO NO

Angulate parallel to AC-PC line, then tilt 15 degrees toward TOP of head

Angulate parallel to AC-PC line, then tilt 15 degrees toward TOP of head. Send source images to PACS

image

2D AXIAL fMRI RESTING NO NO

Same as Axial Field Map

Same as Axial Field Map

Instruct subject to KEEP EYES OPEN AND STAY AWAKE for duration of scan (10 minutes).

Send source images to PACS
.

REPEAT SAG 3D T1 TFE NO NO Same as prior Same parameters as prior.