MR Pediatric Brain WO-Ingenia Protocol

Revised 2/8/2019
Charge for Brain WO

Ingenia Scanners Only: MR4, MR2, DMR2, Beaverton

0 Months to 2 Years - 3mm Slices, 1mm Gap
2 Years to 9 Years- 4mm Slices 1mm Gap
Above 9 years use Adult Protocol
Head Coil
Plane Weighting Mode Slice Gap FAT SAT FOV Scan Range
AXIAL T2 TSE 3-4mm 1mm None 20cm Angle to Corpus- Skull Base to Vertex
AXIAL T1 TSE 3-4mm 1mm None 20cm Angle to Corpus- Skull Base to Vertex
3D AXIAL SWI 1 FFE 2mm -1mm None 20cm Angle to Corpus- Skull Base to Vertex.
OK to add slices.
AXIAL DWI 2mm Voxel SE EPI 3mm 0.3mm SPIR 20cm Angle to Corpus- Skull Base to Vertex
COR 3D TFE 3D GRE 1mm 0mm None 20cm Frontal through Occipital Bone.
Generate SAG MPR from this sequence.
COR FLAIR TSE 3-4mm 1mm None 20cm Frontal through Occipital Bone
3D COR FLAIR BRAINVIEW TSE IR - 0mm None 25cm Frontal through Occipital Bone
Angle perpendicular to corpus
OK to add slices
MR Peds brain & orbits w/wo 0-2 yrs old