MR Pediatric Brain W/WO Protocol-Ingenia

Revised- 2/8/2019
Charge for Brain W/WO
Ingenia Scanners Only: M4, MR2, DMR2, Beaverton

0 Months to 2 Years - 3mm Slices, 1mm Gap
2 Years to 9 Years - 4mm Slices, 1mm Gap
Above 9 years use Adult Protocol
Head Coil. Ingenia Systems Only
Plane Weighting Mode Slice Gap FAT SAT FOV Scan Range
SAG T1 TSE 3-4mm 1mm None 20cm Scalp to Scalp
AXIAL T2 TSE 3-4mm 1mm None 20cm Angle to Corpus- Skull Base to Vertex
AXIAL T1 TSE 3-4mm 1mm None 20cm Angle to Corpus- Skull Base to Vertex
3D AXIAL SWI FFE 2mm -1mm None 20cm Angle to Corpus- Skull Base to Vertex.
OK to add slices.
AXIAL DWI 2mm Voxel SE EPI 3mm 0.3mm SPIR 20cm Angle to Corpus- Skull Base to Vertex
3D COR FLAIR BRAINVIEW TSE IR - 0mm None 25cm Frontal through Occipital Bone.
Angle perpendicular to Corpus.OK to add slices.
CONTRAST INJECTION
COR FLAIR TSE 3-4mm 1mm None 20cm Frontal through Occipital Bone
AXIAL T1 TSE 3-4mm 1mm None 20cm Angle to Corpus- Skull Base to Vertex
COR T1 FAT SAT TSE 3-4mm 1mm SPIR 20cm Frontal through Occipital Bone
SAG T1 TSE 3-4mm 1mm None 20cm Angle to Corpus- Skull Base to Vertex
Optional:SAG 3D T1 SPGR 3D TFE 2MM 0MM None 20cm Optional if specifically protocoled or requested by the order/comments. Scalp to scalp. Generate Axial MPR 2mm skip 0
 
MR Peds brain & orbits w/wo 0-2 yrs old
MR Peds brain & orbits w/wo 0-2 yrs old