MR Brain Tumor Follow Up WWO Neuro Protocol

Last updated:2/14/13
Charge as: Brain WWO
Scanner preference: OK to run this protocol if not scheduled on Ingenia scanner. Preferred on Ingenia scanners (MR4, MR 2, DMR2, BEAVERTON)
Coil: Head

Plane Weighting Mode Slice Gap FAT SAT FOV Notes
SAG T1 TSE 4mm 1mm None 23cm Scalp to Scalp
AXIAL T1 TSE 4mm 1mm None 23cm Angle to Corpus- Skull Base to Vertex
COR Flair TSE 4mm 1mm None 23cm Frontal through Occipital Bone
AXIAL T2* GRE GRE 4mm 1mm None 23cm Angle to Corpus- Skull Base to Vertex
AXIAL DWI 2mm Voxel SE EPI 3mm 0.3mm SPIR 23cm Angle to Corpus- Skull Base to Vertex

Contrast injection

Plane Weighting Mode Slice Gap FAT SAT FOV Notes
AXIAL T2 TSE 4mm 1mm None 23cm Angle to Corpus- Skull Base to Vertex
AXIAL T1 TSE 4mm 1mm None 23cm Angle to Corpus- Skull Base to Vertex
COR T1 FAT SAT TSE 4mm 1mm SPIR 23cm Frontal through Occipital Bone
SAG T1 TSE 4mm 1mm None 23cm Scalp to Scalp
MR Brain WO Neuro Protocol - Ingenia scanner Image