MR Pediatric Bilateral Lower Extremity MRA (run-off) W/WO Protocol

Revised - 8/13/2013
Charge as MRA Bilateral Lower Extremity W/WO
Room 1 or 2 Only
Coil: Body
(REF scan)
Mode Slice Gap FAT SAT FOV Scan Range
Contrast Injection
COR CE 2D T1 FFE 4mm -2 mm* None Fit to Patient Follow ADULT LOWER EXT MRA (RUN OFF) protocol with double-dose pediatric weight-based contrast. 2 or 3 station MRA, depending on patient size. Aortic bifurcation through heels.
Notes: Images must be checked by radiologist or radiology resident before patient leaves.
*Over-contiguous images